NOTE:
      See the document "Summary
of Virtual Temperature Processing in PREPBUFR" for more information.
KEY:
      IN "R.CODE" COLUMN:
                                           
B - OCCURS IN ALL OPERATIONAL VERSIONS OF VIRTMP EXCEPT RUC (THE VIRTMP
STEP DOES NOT RUN IN THE RUC NETWORK).
      IN "MNEMONIC"
COLUMN:
                                           
# - NEW VALUE CALCULATED.
 
| R.CODE | MEANING | MNEMONICS AFFECTED AND NEW VALUE FOR OBS, Q.M. | 
| 00 B | SPECIFIC HUMIDITY OBSERVATION IS REGENERATED FROM REPORTED DEWPOINT TEMPERATURE AND PRESSURE. (DEWPOINT TEMPERATURE HAS UNDERGONE POSSIBLE CQC AND RADIATION CORRECTIONS). THIS IS PERFORMED IN THE W3LIB ROUTINE GBLEVENTS. | QRC-> QOB=# | 
| 00 B | TEMPERATURE OBSERVATION IS CONVERTED TO VIRTUAL TEMPERATURE, CALCULATED FROM THE REGENERATED SPECIFIC HUMIDITY (SEE R. CODE 00 ABOVE OR 01 BELOW) AND FROM A SENSIBLE TEMPERATURE OBSERVATION THAT HAS UNDERGONE POSSIBLE COMPLEX QUALITY CONTROL AND RADIATION CORRECTIONS. THIS IS PERFORMED IN THE W3LIB ROUTINE GBLEVENTS. | TRC-> TOB=# | 
| 01 B | SPECIFIC HUMIDITY OBSERVATION IS REGENERATED FROM REPORTED DEWPOINT TEMPERATURE AND PRESSURE. (DEWPOINT TEMPERATURE HAS UNDERGONE POSSIBLE CQC AND RADIATION CORRECTIONS). THIS IS PERFORMED IN THE PROGRAM PREPOBS_CQCBUFR. | QRC-> QOB=# | 
| 01 B | TEMPERATURE OBSERVATION IS CONVERTED TO VIRTUAL TEMPERATURE, CALCULATED FROM THE REGENERATED SPECIFIC HUMIDITY (SEE R. CODE 00 OR 01 ABOVE) AND FROM A SENSIBLE TEMPERATURE OBSERVATION THAT HAS UNDERGONE POSSIBLE COMPLEX QUALITY CONTROL AND RADIATION CORRECTIONS. THIS IS PERFORMED IN THE PROGRAM PREPOBS_CQCBUFR. | TRC-> TOB=# | 
| 02 B | TEMPERATURE OBSERVATION IS CONVERTED TO VIRTUAL TEMPERATURE, CALCULATED FROM THE REGENERATED SPECIFIC HUMIDITY (SEE R. CODE 00 OR 01 ABOVE) AND FROM A SENSIBLE TEMPERATURE OBSERVATION THAT HAS UNDERGONE POSSIBLE COMPLEX QUALITY CONTROL AND RADIATION CORRECTIONS. EITHER THE SPECIFIC HUMIDITY HAS A REJECTED QUALITY MARKER OTHER THAN 9 OR 15 - OR - THE SPECIFIC HUMIDITY HAS A REJECTED QUALITY MARKER OF 9 OR 15 AND THE SENSIBLE TEMPERATURE QUALITY MARKER IS REJECTED BUT WITH A VALUE OTHER THAN 9 OR 15. VIRTUAL TEMPERATURE IS CONSIDERED REJECTED. THIS IS VALID ONLY FOR SURFACE LAND OR MARINE DATA TYPES. THIS IS PERFORMED IN THE W3LIB ROUTINE GBLEVENTS. | TRC-> TOB=#, TQM=8 | 
| 03 B | REPORTED TEMPERATURE OBSERVATION IS ALREADY VIRTUAL. NO CONVERSION IS NECESSARY. THIS IS PERFORMED IN THE W3LIB ROUTINE GBLEVENTS. | TRC-> no values changed | 
| 04 B | TEMPERATURE OBSERVATION IS CONVERTED TO VIRTUAL TEMPERATURE, CALCULATED FROM THE REGENERATED SPECIFIC HUMIDITY (SEE R. CODE 00 OR 01 ABOVE) AND FROM A SENSIBLE TEMPERATURE OBSERVATION THAT HAS UNDERGONE POSSIBLE COMPLEX QUALITY CONTROL AND RADIATION CORRECTIONS. THE SPECIFIC HUMIDITY HAS A REJECTED QUALITY MARKER OF 9 OR 15 AND THE SENSIBLE TEMPERATURE QUALITY MARKER IS EITHER NOT REJECTED OR IS REJECTED BUT WITH A VALUE OF 9 OR 15. VIRTUAL TEMPERATURE IS CONSIDERED REJECTED. THIS IS VALID ONLY FOR SURFACE LAND OR MARINE DATA TYPES. THIS IS PERFORMED IN THE W3LIB ROUTINE GBLEVENTS. | TRC-> TOB=#, TQM=9 (see % below) | 
| 06 B | TEMPERATURE OBSERVATION IS CONVERTED TO VIRTUAL TEMPERATURE, CALCULATED FROM THE REGENERATED SPECIFIC HUMIDITY (SEE R. CODE 00 OR 01 ABOVE) AND FROM A SENSIBLE TEMPERATURE OBSERVATION THAT HAS UNDERGONE POSSIBLE COMPLEX QUALITY CONTROL AND RADIATION CORRECTIONS. THE SPECIFIC HUMIDITY HAS A REJECTED QUALITY MARKER OTHER THAN 9 OR 15, THE PRESSURE LEVEL IS BELOW 700 MB, AND THE SENSIBLE TEMPERATURE QUALITY MARKER IS EITHER 1, 2 OR 3. VIRTUAL TEMPERATURE IS CONSIDERED SUSPECT. THIS IS VALID ONLY FOR RADIOSONDE, DROPWINSONDE, AND MULTI-LEVEL RECONNAISSANCE DATA TYPES. THIS IS PERFORMED IN THE W3LIB ROUTINE GBLEVENTS. | TRC-> TOB=#, TQM=3 | 
| 07 B | TEMPERATURE OBSERVATION IS CONVERTED TO VIRTUAL TEMPERATURE, CALCULATED FROM THE REGENERATED SPECIFIC HUMIDITY (SEE R. CODE 00 OR 01 ABOVE) AND FROM A SENSIBLE TEMPERATURE OBSERVATION THAT HAS UNDERGONE POSSIBLE COMPLEX QUALITY CONTROL AND RADIATION CORRECTIONS. THE SPECIFIC HUMIDITY HAS A REJECTED QUALITY MARKER OTHER THAN 9 OR 15, THE PRESSURE LEVEL IS BELOW 700 MB, AND THE SENSIBLE TEMPERATURE QUALITY MARKER IS EITHER 1, 2 OR 3. VIRTUAL TEMPERATURE IS CONSIDERED SUSPECT. THIS IS VALID ONLY FOR RADIOSONDE, DROPWINSONDE, AND MULTI-LEVEL RECONNAISSANCE DATA TYPES. THIS IS PERFORMED IN THE PROGRAM PREPOBS_CQCBUFR. | TRC-> TOB=#, TQM=3 |